Reference sheet
Mini
AH-MIN-24
Reference sheet details
Detailed specifications, operating steps, and safety notes extracted from the product reference sheet and translated for this page.
- Product
- Mini
- Model
- AH-MIN-24

- Heating area
- Up to 45 m²
- Fuel consumption
- 0.14 - 0.24 L/hr
Product sheet specifications
01Measurements and capacity
- Length 44 cm, width 54 cm, height 80 cm.
- Total heater weight 25.6 kg ± 2%.
- Average heating area 25 m² ± 20%.
- External diesel tank, 7 liter capacity.
- Diesel regulator: carburetor.
Features
- The combustion unit includes an air sharraq that closes automatically after ignition, protecting the unit from the puncture that can happen with manual-sharraq devices.
- The full mouth of the combustion unit is made from cast iron to protect the unit from damage and simplify maintenance.
- High-quality oven-baked heat-resistant paint.
- Wide glass front, 143 x 254 x 4 mm, providing a larger viewing area for the fire.
Operating details
02Preparation
- Fill the fuel tank with clean diesel up to the marked line inside the filter.
Chimney sharraq
- On sunny days, and to remove cold air collected inside the chimney, take a cloth piece, fold it into a small ball, wet it with diesel, and light it inside the heater elbow.
- This step is known as chimney sharraq. It is necessary to warm the chimney and speed up ignition.
Starting
- Place the supplied wick thread under the combustion unit to make ignition easier.
- Set the regulator indicator to the middle position.
- After finishing the chimney sharraq step, open the tank valve six full turns.
- Confirm diesel has reached the unit by looking below the combustion unit.
- Using the dedicated lighter or a match, ignite the diesel inside the combustion unit.
- If ignition does not start, look for the cause in dirty diesel or weak chimney draft.
Care and safety notes
03Important notes
- Adjust the heater legs so the heater becomes completely level, then lock the bracket after adjustment.
- Make sure the heater stands perfectly level on the floor to ensure the diesel regulator works correctly.
- At the end of winter, empty the diesel tank completely and clean it thoroughly with a cloth.
- Do not use chemicals or water to clean the combustion unit, to protect the device from damage.