Heating area
Up to 78 m²
Fuel consumption
0.24 - 0.38 L/hr

Product sheet specifications

01

Measurements and capacity

  • Length 64 cm, width 40 cm, height 80 cm.
  • Total heater weight 38 kg ± 2%.
  • Average heating area 60 m² ± 20%.
  • Internal diesel tank, 7 liter capacity.
  • Diesel regulator: carburetor.
  • Control device included.

Features

  • Automatic operation for all heater circuit stages with one touch using the remote control or touch buttons.
  • Two-speed turbine fan for pushing hot air.
  • Sharraq fan helps the unit ignite faster.
  • Electronic igniter.
  • High-quality oven-baked heat-resistant paint.
  • Wide glass front, 143 x 254 x 4 mm, providing a larger viewing area for the fire.

Operating details

02

Preparation

  • Fill the fuel tank with clean diesel up to the marked line inside the filter, then connect the heater cable to a 220V power outlet.

Starting

  • Set the regulator indicator to the middle position.
  • Press the ON button from the remote control, or the ignition button on the heater control board, and wait until the igniter glows fully red, about 20 seconds.
  • Open the diesel valve six full turns. The program then runs automatically for 15 minutes, starting with the igniter, then the sharraq fan, then the turbine fan.

Manual control

  • At any time, you can stop the circuit program and directly control the igniter, sharraq fan, or turbine speed as needed.

If ignition does not start

  • Raise the regulator indicator two marks, then press the start button again.
  • Do not repeat this attempt more than two consecutive times, because it can damage the igniter.
  • If ignition failure repeats, check for dirty diesel, weak chimney draft, or low electrical voltage.

Care and safety notes

03

Important notes

  • Adjust the heater legs so the heater becomes completely level, then lock the bracket after adjustment.
  • Make sure the heater stands perfectly level on the floor to ensure the diesel regulator works correctly.
  • On sunny days, and to remove cold air collected inside the chimney, take a cloth piece, fold it into a small ball, wet it with diesel, and light it inside the heater elbow.
  • At the end of winter, empty the diesel tank completely and clean it thoroughly with a cloth.
  • Do not use chemicals or water to clean the combustion unit, to protect the device from damage.